Location:  Home » Products » Panasonic Automation Series » Panasonice PLC Series
 
Panasonic PLC FP-X0 Series

Units


  • Control units
  • Expansion units [FP-X]
  • Expansion units [FP0R]
  • Intelligent units[Units in common with FP0]
  • Link and Communication units[Units in common with FP0]
  • Other cables and maintenance parts



Control units

L14R L30R L40R/L40MR L60R/L60MR
Product name Power supply Specifications Part No.
  Program
capacity
Analog
input
RS485
communication
FP-X0
L14R
100 to 240 V AC 24 V DC input, 8 points
0.5 A/5 to 24 V DC transistor output, 2 points
2 A relay output, 4 points
2.5 k steps - - AFPX0L14R
FP-X0
L30R
100 to 240 V AC 24 V DC input, 16 points
0.5 A/5 to 24 V DC transistor output, 4 points
2 A relay output, 10 points
2.5 k steps - - AFPX0L30R
FP-X0
L40R
100 to 240 V AC 24 V DC input, 24 points
0.5 A/5 to 24 V DC transistor output, 4 points
2 A relay output, 12 points
8 k steps 10 bits,
2 channel
- AFPX0L40R
FP-X0
L40MR
100 to 240 V AC 24 V DC input, 24 points
0.5 A/5 to 24 V DC transistor output, 4 points
2 A relay output, 12 points
8 k steps 10 bits,
2 channel
Available AFPX0L40MR
FP-X0
L60R
100 to 240 V AC 24 V DC input, 32 points
0.5 A/5 to 24 V DC transistor output, 4 points
2 A relay output, 24 points
8 k steps 10 bits,
2 channel
- AFPX0L60R
FP-X0
L60MR
100 to 240 V AC 24 V DC input, 32 points
0.5 A/5 to 24 V DC transistor output, 4 points
2 A relay output, 24 points
8 k steps 10 bits,
2 channel
Available AFPX0L60MR

Note) 24 V DC input: ± common

Return to top


Expansion units [FP-X]

Input Unit / Output unit

Product name Power supply Specifications Part number
FP-X E16X 
Expansion Input Unit
-
(Power is supplied from the left-side Unit.)
24 V DC, 16 input points *1 AFPX-E16X
FP-X E14YR 
Expansion Output Unit
-
(Power is supplied from the left-side Unit.)
2A relay, 14 output points *1 AFPX-E14YR

I/O Unit (Relay output)

Product name Power supply Specifications Part number
FP-X E16R 
Expansion I/O Unit
-
(Power is supplied from the left-side Unit.)
8-point input of 24 V DC,
8-point relay output of 2 A *1
AFPX-E16R
FP-X E30R 
Expansion I/O Unit
100~240V AC 16-point input of 24 V DC,
14-point relay output of 2 A *2
AFPX-E30R
FP-X E30RD 
Expansion I/O Unit
24V DC 16-point input of 24 V DC,
14-point relay output of 2 A *2
AFPX-E30RD

I/O Unit (Transistor output)

Product name Power supply Specifications Part number
FP-X E16T 
Expansion I/O Unit
-
(Power is supplied from the left-side Unit.)
8-point input of 24 V DC,
8-point transistor (NPN) output of 0.5 A *1
AFPX-E16T
FP-X E16P 
Expansion I/O Unit
-
(Power is supplied from the left-side Unit.)
8-point input of 24 V DC,
8-point transistor (PNP) output of 0.5 A *1
AFPX-E16P
FP-X E30TD 
Expansion I/O Unit
24V DC 16-point input of 24 V DC,
14-point transistor (NPN) output of 0.5 A *2
AFPX-E30TD
FP-X E30T 
Expansion I/O Unit
100~240V AC 16-point input of 24 V DC,
14-point transistor (NPN) output of 0.5 A *2
AFPX-E30T
FP-X E30PD 
Expansion I/O Unit
24V DC 16-point input of 24 V DC,
14-point transistor (PNP) output of 0.5 A *2
AFPX-E30PD
FP-X E30P 
Expansion I/O Unit
100~240V AC 16-point input of 24 V DC,
14-point transistor (PNP) output of 0.5 A *2
AFPX-E30P

Expansion FP0 Adapter

Product name Power supply Specifications Part number
Expansion FP0 Adapter 24VDC Up to 3 FP0R expansion Units can be connected via an adapter.With an 8cm extension cable and power cable AFPX-EFP0
* The 24 V DC inputs of all Units are bi-directional (sink/source) inputs.
*1 Two or more E16T cannot be connected serially because it cannot supply the power to other units. With an 8cm extension cable
*2 Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable
*3 Up to 3 Units can be connected. Expansion FP0 Adapter is required.

Return to top


Expansion units [FP0R]

Product name Specications Part number
Number of I/O points Power supply
voltage
Input Output Connection type
FP0R-E8
Expansion Unit
8 Input: 8 - 24 V DC
Sink/Source
(±common)
- MIL connector AFP0RE8X
8 Input: 4
Output: 4
24 V DC 24 V DC
Sink/Source
(±common)
Relay: 2 A Terminal block AFP0RE8RS
Molex connector AFP0RE8RM
8 Output: 8 24 V DC - Relay: 2 A Terminal block AFP0RE8YRS
8 Output: 8 - - Transistor NPN: 0.3 A MIL connector AFP0RE8YT
8 Output: 8 - - Transistor NPN: 0.3 A MIL connector AFP0RE8YP
FP0R E16
Expansion Unit
16 Input: 16 - 24 V DC
Sink/Source
(±common)
- MIL connector AFP0RE16X
16 Input: 8
Output: 8
24 V DC 24 V DC
Sink/Source
(±common)
Relay: 2 A Terminal block AFP0RE16RS
Molex connector AFP0RE16RM
16 Input: 8
Output: 8
- 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.3 A MIL connector AFP0RE16T
16 Input: 8
Output: 8
- 24 V DC
Sink/Source
(±common)
Transistor PNP: 0.3 A MIL connector AFP0RE16P
16 Output: 16 - - Transistor NPN: 0.3 A MIL connector AFP0RE16YT
16 Output: 16 - - Transistor PNP: 0.3 A MIL connector AFP0RE16YP
FP0R E32
Expansion Unit
32 Input: 16
Output: 16
- 24 V DC
Sink/Source
(±common)
Transistor NPN: 0.3 A MIL connector AFP0RE32T
32 Input: 16
Output: 16
- 24 V DC
Sink/Source
(±common)
Transistor PNP: 0.3 A MIL connector AFP0RE32P
*1 The relay output type expansion units come with a power cable (part number: AFP0581).
(The transistor output type expansion units need no power cable.)
*2 The terminal block type relay output units have two terminal blocks (9 pins) made by Phoenix.
Use a 2.5 mm 0.10 inch wide screwdriver. Preferably use the specific terminal block screwdriver (part number: AFP0806, Phoenix type code SZS0, 4 x 2.5 mm 0.10 inch) or equivalent.
*3 The connector type relay output units have two connectors made by Nihon Molex (Molex type code 51067-0900, 9 pins). Use the specific Molex connector press-fit tool (part number: AFP0805, Nihon Molex type code 57189-5000) or equivalent.
*4 The transistor output units have a press-fit socket for wire-pressed terminal cable and contacts. Use the press-fit tool (part number: AXY52000FP) for wire-pressed terminal cable.

Return to top


Intelligent units[Units in common with FP0]

Product name Specications Product number Part number
FP0 Analog I/O Unit Input specifications
Number or channels : 2 channels
Input range : Voltage 0 to 5 V, -10 to +10 V (Resolution: 1/4000)
Current 0 to 20 mA (Resolution: 1/4000)
FP0-A21 AFP0480
Output specifications
Number or channels : 1 channel
Output range : Voltage -10 to +10 V (Resolution: 1/4000)
Current 0 to 20 mA (Resolution: 1/4000)
FP0 A/D Converter Unit Input specifications
Number or channels : 8 channels
Input range : Voltage 0 to 5 V, -10 to +10 V, -100 to 100 mV (Resolution: 1/4000)
Current 0 to 20 mA (Resolution: 1/4000)
FP0-A80 AFP0401
FP0 D/A Converter Unit Output specifications
Number or channels : 4 channels
Output range : (Voltage output type) -10 to +10 V (Resolution: 1/4000)
(Current output type) 4 to 20 mA (Resolution: 1/4000)
FP0-A04V AFP04121
FP0-A04I AFP04123
FP0 Thermocouple Unit K, J, T and R thermocouple, Resolution: 0.1°C FP0-TC4 AFP0420
K, J, T and R thermocouple, Resolution: 0.1°C FP0-TC8 AFP0421

Return to top


Link and Communication units[Units in common with FP0]

Link and Communication units[Units in common with FP0]
Product name Specications Power supply
voltage
Product number Part number
FP0 CC-Link Slave Unit This unit is for making the FP0 function as a slave station of the CC-Link.
Only one unit can be connected to the furthest right edge of the FP0 expansion bus.
Note : Accuracy will change if an FP0 thermocouple unit is used at the same time.
For details, please refer to the catalog or to the CC-Link Unit manual.
24 V DC FP0-CCLS AFP07943
FP0 I/O Link Unit This is a link unit designed to make the FP0 function as a station to MEWNET-F (remote I/O system). 24 V DC FP0-IOL AFP0732

Return to top


Other cables and maintenance parts

Product name Specifi cations Part No.
Backup battery For data storage backup and calender/clock
backup
AFP8801
FP-X expansion cable (Note) 8cm AFPX-EC08
30cm AFPX-EC30
80cm AFPX-EC80
Cable for FP and computer
connection (M5 type)
3 m Round D-SUB, 9-pin, L-shaped type AFC8503
Round D-SUB, 9-pin, Straight type AFC8503S
Power cable for FP0 For the adaptor for FP0 expansion, 1 m long AFP0581
Installation bracket for FP0
(Long-strip type)
For FP0 expansion unit, 10 pieces per
package
AFP0803

Note) The cables for expansion can be extended to 160 cm max.